Technical Details of Coldrooms
TECHNICAL DETAILS OF COLD ROOMS
TONNES
(Vol/100) |
MEASUREMENT (Ft) L X B X H |
HORSE POWER (HP) |
RECOMMENDED GENERATOR. NB.SOLAR POWER REQUIREMENTS SHALL BE PROVIDED UPON REQUEST |
5 |
8ft X 8ft X 8ft |
3 |
12.5KVA |
6 |
10ft X 8ft X 8ft |
3.5 |
15KVA
|
10 |
16ft X 8ft X 8ft |
4 Single Unit |
18KVA |
12 |
20ft X 8ft X 8ft |
5 Single Unit |
20KVA |
16 |
20ft X 10ft X 8ft |
5 Double Units |
25KVA |
20 |
20ft X 10ft X 10ft |
6 Double Units |
27KVA |
25 |
28ft X 12ft X 8ft |
6.2 Double Units |
30KVA
|
30 |
20ft X 20ft X 8ft |
7.2 Double Units |
33KVA
|
40 |
32ft X 16ft X 8ft |
7.5 Double Units |
35KVA
|
50 |
26ft X 20ft X 10ft |
8 Double Units |
40KVA
|
100 |
54ft X 20ft X 10ft |
Depending on Design |
45KVA
|
150 |
64ft X 20ft X 12ft |
‘’ |
60KVA
|
200 |
64ft X 20ft X 16ft |
‘’ |
65KVA
|
500 |
124ft X 20ft X 20ft |
‘’ |
70KVA
|
NB: WE SHALL PROVIDE BREAKDOWN COST INCLUDING LOGISTIC AND DELIVERY COST WHEN YOU REQUEST FOR A QUOTE.
ALL PRICES ATTRACTS 7.5%VAT AND EXCLUDE DELIVERY FEE. Warranty is 12months. Delivery is 2 weeks.
Door Curtain: PVC Strip Curtains
Coldroom Light: 18W fluorescent light
DENSITY OF PU PANEL = 42kg/m3 with Tolerance of 3kg/m3
Cold Room Insulation:
PU (Polyurethane Sandwich Panel) = Minimum of 100mm thickness and Maximum of 200mm thickness.
Colour: White/Off-white
Sealant: ABBRO Silicon
Grip Type: Camlock/Interlock
CONDENSING UNIT
The Condensing Unit Consists of:
- Compressor
- Condenser
- Double fan for heat extraction
- Liquid Receiver
- Oil Separator
- Low and High Pressure Switch
- Drier/Filter
- Vibration Absorber
- Solenoid Valve
- Sight Glass
COMPRESSOR TYPE:
Hermatic/Semi Hermatic
The Evaporator shall consist of:
- Evaporator Coil
- Aluminum Casing
- Double fan
- Expansion Valve
- Heater
ELECTRICAL PANEL BOX:
An electrical panel control box containing different types of sophisticated protecting devices e.g Phase monitor, Contactor, Circuit Breaker, Delay Timer, Overload Monitor etc. will be installed to protect the units against abnormal voltage, incomplete voltage, fluctuating current, overloading and also soft touch switch for easy ON/OFF several indicator lights for easy identification of fault and user friendly.
Other Components includes:
- Thermostat
- Digital Thermometer
- Phase failure monitoring device
- Contactors
- Circuit Breaker
- Overload Protector
- Timer or Time Delay Relay
- Defrost Timer
- 11/8 ″ Pipe for return line
- 7/8″Pipe for liquid line
TECHNICAL DETAILS OF OUR BLAST FREEZERS:
Kg(s) |
MEASUREMENT (ft) LXBXH |
COMPRESSOR SIZE (HP) |
300Kg |
6ft X 4ft X 8ft |
5HP |
500Kg
|
8ft X 8ft X 8ft |
7.5HP |
700Kg
|
10ft X 8ft X 8ft |
10HP |
1000Kg
|
16ft X 8ft X 8ft |
DEPENDS ON THE DESIGN |
1500Kg
|
20ft X 8ft X 8ft |
DEPENDS ON THE DESIGN |